Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
BMC Cardiovasc Disord ; 23(1): 609, 2023 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-38087189

RESUMO

BACKGROUND: There is a lack of evidence regarding contemporary implantable cardioverter-defibrillator (ICD) battery longevity. Our aim was to assess battery longevity in ICDs in a real-world setting. METHODS: Retrospective cross-sectional single center study of a prospectively collected database of consecutive patients who underwent ICD implantation from January 2010 to December 2015. Clinical data and battery longevity of all manufacturers were collected. RESULTS: A total of 351 patients (84.6% males, mean age of 61 ± 12 years) were included in the study (292 VVI; 6 VDD; 53 DDD). All manufacturers (Abbott, Biotronik, Boston, Medtronic and Microport) were equally represented in the study (p = 0.110). Median battery longevity was 10.8 years (11 years for VVI and 8.5 for DDD). After a follow-up time of 5 years, 98% of VVI and DDD were still in service (vs. industry-projected longevity of 98%). During this time, 89 patients (25.4%) underwent device replacement - 69 patients (77.5%) due to battery depletion, 6 patients due to infection, 3 patients due to dysfunction and 13 patients due to upgrade to CRT-D. Patients with Medtronic or Biotronik ICDs had a greater probability of being replaced earlier due to battery depletion (Biotronik HR 6.87, 95% CI 2.54-18.58, p < 0.001; Medtronic HR 6.08, 95% CI 2.45-15.06 p < 0.001). CONCLUSIONS: VVI and DDD ICD battery longevity matched industry-projected longevity after 5 years of follow-up. Medtronic and Biotronik ICDs appeared to have an earlier battery depletion. Further randomized studies are required to ensure optimal care.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Falha de Equipamento , Estudos Retrospectivos , Estudos Prospectivos , Estudos Transversais , Desenho de Equipamento , Estimativa de Kaplan-Meier , Fatores de Tempo , Remoção de Dispositivo
2.
Cardiol Young ; : 1-6, 2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37828640

RESUMO

INTRODUCTION: Cardiac arrhythmias are a major concern in patients with CHD. The purpose of this study was to evaluate the long-term outcomes in patients with CHD submitted to catheter ablation. MATERIALS AND METHODS: Observational retrospective study of patients with CHD referred for catheter ablation from January 2016 to December 2021 in a tertiary referral centre. Acute procedural endpoints and long-term outcomes were assessed. RESULTS: A total of 44 ablation procedures were performed in 36 CHD patients (55% male, mean age 43 ±3 years). Fifty-four arrhythmias were ablated: 23 cavotricuspid isthmus atrial flutters, 10 atrial re-entrant tachycardias, eight focal atrial tachycardias, eight atrial fibrillations, three atrioventricular re-entrant tachycardias, and two ventricular tachycardias. During a median follow-up time of 37 months (interquartile range 12-51), freedom from arrhythmia recurrence was achieved in 93%, with 1.2 procedures per patient (18% with anti-arrhythmic drugs). There were no adverse events related to catheter ablation. No predictors of recurrence were identified. CONCLUSION: In patients with CHD, catheter ablation presents a high mid-term efficacy while maintaining a safe profile.

3.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37345859

RESUMO

AIMS: Pulmonary vein isolation (PVI) guided by the Ablation Index (AI) has shown high acute and mid-term efficacy in the treatment of paroxysmal atrial fibrillation (AF). Previous data before the AI-era had suggested that wide-area circumferential ablation (WACA) was preferable to ostial ablation. However, with the use of AI, we hypothesize that ostial circumferential ablation is non-inferior to WACA and can improve outcomes in paroxysmal AF. METHODS AND RESULTS: Prospective, multicentre, non-randomized, non-inferiority study of consecutive patients were referred for paroxysmal AF ablation from January 2020 to September 2021. All procedures were performed using the AI software, and patients were separated into two different groups: WACA vs. ostial circumferential ablation. Acute reconnection, procedural data, and 1-year arrhythmia recurrence were assessed. During the enrolment period, 162 patients (64% males, mean age of 60 ± 11 years) fulfilled the study inclusion criteria-81 patients [304 pulmonary vein (PV)] in the WACA group and 81 patients (301 PV) in the ostial group. Acute PV reconnection was identified in 7.9% [95% confidence interval (CI), 4.9-11.1%] of PVs in the WACA group compared with 3.3% (95% CI, 1.8-6.1%) of PVs in the ostial group [P < 0.001 for non-inferiority; adjusted odds ratio 0.51 (95% CI, 0.23-0.83), P = 0.05]. Patients in the WACA group had longer ablation (35 vs. 29 min, P = 0.001) and procedure (121 vs. 102 min, P < 0.001) times. No significant difference in arrhythmia recurrence was seen at 1-year of follow-up [11.1% in WACA vs. 9.9% in ostial, hazard ratio 1.13 (95% CI, 0.44-1.94), P = 0.80 for superiority]. CONCLUSION: In paroxysmal AF patients treated with tailored AI-guided PVI, ostial circumferential ablation is not inferior to WACA with regard to acute PV reconnection, while allowing quicker procedures with less ablation time.


Assuntos
Fibrilação Atrial , Veias Pulmonares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Razão de Chances , Veias Pulmonares/cirurgia , Software
4.
Insects ; 14(4)2023 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-37103181

RESUMO

Maize grains represent a significant contribution for assuring food safety all over the globe. Sitophilus zeamais (Motschulsky) (Coleoptera: Curculionidae), also known as the maize weevil, is one of the most destructive pests in stored maize, causing qualitative and quantitative losses. To control S. zeamais populations in maize storage sites, synthetical chemical insecticides are applied. However, these are often used wastefully, have environmental implications, and can induce the development of resistant populations. In this work, the insecticidal and grain protecting efficacy of an innovative macro-capsule delivery device, loaded with essential oils from Clove bud and Pennyroyal, as well as their combined solutions, was tested against naturally S. zeamais-infested maize grains. The blend of both compounds incorporated in a controlled release device reduced losses by more than 45% over a long storage period of twenty weeks, diminishing the survivability of maize weevils by over 90%. The usage of the blend at a concentration of 370 µL⋅Lair-1 with an antioxidant showed the best results, however, by halving the concentration (185 µL⋅Lair-1), a significant control of S. zeamais populations was still achieved.

5.
Int J Cardiol ; 383: 33-39, 2023 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-37116756

RESUMO

PURPOSE: We aim to evaluate whether the use of a multielectrode mapping catheter could lead to higher efficacy of premature ventricular contraction (PVC) ablation. METHODS: Prospective, multicenter nonrandomized study of consecutive patients referred for PVC ablation from January 2018 to June 2021. Patients were separated into two groups: activation map performed with the PentaRay catheter (Study group) or with the ablation catheter (Control group). PMF software was used in both groups. Procedural endpoints and 1-year freedom from ventricular arrhythmia were assessed. RESULTS: During the enrollment period 136 patients (60% males, mean age of 55 ± 17 years, 60% left-sided origin) fulfilled the inclusion criteria - 68 patients in each group. Patients in the Study Group had a sevenfold higher number of acquired activation points (768 ± 728 vs. 110 ± 79, p < 0.01), a shorter mapping time (28 ± 19 min vs. 49 ± 32 min, p < 0.01) and a quicker procedure time (110 ± 33 min vs. 134 ± 50 min, p < 0.01), compared to patients in the Control Group. While there were no significant differences in the acute success (95.6% in the Study Group vs. 90.1% in Control group, p = 0.49), or adverse events (4% in the Study group vs. 7% in the Control group, p = 0.72), patients in the Study group had a higher freedom from ventricular arrhythmia at 1-year (89.7% vs. 70.6%, p = 0.01). The use of the PentaRay catheter was an independent predictor of success (HR = 6.20 [95% CI, 1.08-35.47], p = 0.003). CONCLUSIONS: The use of the PentaRay catheter may improve the outcome of PVC ablation while reducing procedure time.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Estudos Prospectivos , Cateteres , Software , Fatores de Tempo , Ablação por Cateter/métodos , Resultado do Tratamento
6.
Front Oncol ; 13: 1074337, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36910629

RESUMO

Background: Current prognosis in oncology is reduced to the tumour stage and performance status, leaving out many other factors that may impact the patient´s management. Prognostic stratification of early stage non-small-cell lung cancer (NSCLC) patients with poor prognosis after surgery is of considerable clinical relevance. The objective of this study was to identify clinical factors associated with long-term overall survival in a real-life cohort of patients with stage I-II NSCLC and develop a prognostic model that identifies features associated with poor prognosis and stratifies patients by risk. Methods: This is a cohort study including 505 patients, diagnosed with stage I-II NSCLC, who underwent curative surgical procedures at a tertiary hospital in Madrid, Spain. Results: Median OS (in months) was 63.7 (95% CI, 58.7-68.7) for the whole cohort, 62.4 in patients submitted to surgery and 65 in patients submitted to surgery and adjuvant treatment. The univariate analysis estimated that a female diagnosed with NSCLC has a 0.967 (95% CI 0.936 - 0.999) probability of survival one year after diagnosis and a 0.784 (95% CI 0.712 - 0.863) five years after diagnosis. For males, these probabilities drop to 0.904 (95% CI 0.875 - 0.934) and 0.613 (95% CI 0.566 - 0.665), respectively. Multivariable analysis shows that sex, age at diagnosis, type of treatment, ECOG-PS, and stage are statistically significant variables (p<0.10). According to the Cox regression model, age over 50, ECOG-PS 1 or 2, and stage ll are risk factors for survival (HR>1) while adjuvant chemotherapy is a good prognostic variable (HR<1). The prognostic model identified a high-risk profile defined by males over 71 years old, former smokers, treated with surgery, ECOG-PS 2. Conclusions: The results of the present study found that, overall, adjuvant chemotherapy was associated with the best long-term OS in patients with resected NSCLC. Age, stage and ECOG-PS were also significant factors to take into account when making decisions regarding adjuvant therapy.

7.
Rev Port Cardiol ; 42(8): 683-691, 2023 08.
Artigo em Inglês, Português | MEDLINE | ID: mdl-36958571

RESUMO

INTRODUCTION AND OBJECTIVES: There has been increasing interest in pacing methods that provide physiological stimulation, such as His bundle pacing (HBP) or left bundle branch area pacing (LBBAP). Our goal was to assess the feasibility and safety of these techniques. METHODS: Prospective observational single-center study evaluating 46 patients with indication for a pacemaker that attempted HBP or LBBAP from July 2020 to November 2021. Procedural endpoints and pacing parameters were assessed and compared at implantation and three-month follow-up. RESULTS: Overall acute procedural success was achieved in 96% of the cases. Successful HBP was achieved in 91% of the patients and all patients for LBBAP. During implantation, HBP patients presented a higher capture threshold (0.80 [0.55-1.53] V vs. 0.70 [0.40-0.90] V, p=0.08) and lower R-wave amplitude (4.0 [2.9-6.2] mV vs. 7.8 [5.5-10.5] mV, p=0.001) compared to LBBAP patients. There was no difference between groups, either acutely or at 3-months, regarding paced QRS duration (125±22 ms vs. 133±16 ms, p=0.08; 118±16 ms vs. 124±14 ms, p=0.19). Although procedural time was similar with both techniques (95 [75-139] min vs. 95 [74-116] min, p=0.79), fluoroscopy time was significantly reduced during LBBAP (8.1 [5.3-13.4] min vs. 4.1 [3.1-11.3] min, p=0.05). At 3 months of follow-up, the pacing threshold remained with a stable profile in HBP as in LBBAP (1.25 [0.75-2.00] V, p=0.09 and 0.60 [0.50-0.80] V, p=0.78), respectively. The need for re-intervention occurred in 3 (6.5%) HBP cases during follow-up. CONCLUSION: This first national study demonstrates the feasibility and safety of the HBP and LBBAP in patients with pacemaker indication.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Humanos , Estimulação Cardíaca Artificial/métodos , Estudos de Viabilidade , Eletrocardiografia/métodos , Sistema de Condução Cardíaco , Resultado do Tratamento
8.
Int J Cardiol ; 370: 209-214, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36228764

RESUMO

AIMS: To compare the two different ablation strategies, both guided by the Ablation Index (AI), in the setting of atrial fibrillation (AF) ablation: high-power short-duration (HPSD) ablation using 40 W on the posterior wall and 50 W elsewhere versus low-power long-duration (LPLD) using 25 W posteriorly and 35 W elsewhere. METHODS: Prospective, multicenter nonrandomized, noninferiority study of consecutive patients referred for paroxysmal AF ablation from January 2018 to July 2019. Ablation was guided by the AI (≥500 for anterior segments, ≥450 for the roof and inferior segments and 400 posteriorly) and an interlesion distance (ILD) ≤ 6 mm. Patients were separated into two groups: HPSD vs LPLD. Acute reconnection (after adenosine trial) and 2-year outcomes were assessed. RESULTS: 160 patients (61% males, median age of 62 [IQR 51-69] years), fulfilled the study inclusion criteria - 80 patients (316 pulmonary veins [PV]) in the HPSD group and 80 patients (314 PV) in the LPLD. The probability of acute PV reconnection was similar between both groups: 2.2% in HPSD, 95%CI 0.6% to 3.8% vs. 3.4% in LPLD, 95%CI 1.4% to 5.4%; p < 0.001 for noninferiority. Median PV ablation time (20 min vs 30 min, p < 0.01) and procedure duration (80 min vs 100 min, p < 0.001) were shorter in the HPSD group. After a median follow-up of 26 months, arrhythmia recurrence was similar between groups (17.5% in HPSD group vs. 18.8% in LPLD group, p = 0.79). CONCLUSIONS: In paroxysmal AF patients treated with the Ablation Index, a HPSD strategy is noninferior to the more standard LPLD ablation, while allowing for quicker procedures with shorter ablation times.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Estudos Prospectivos , Resultado do Tratamento , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Recidiva
9.
Front Cardiovasc Med ; 9: 1062858, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36531707

RESUMO

Background: Immune checkpoint inhibitors (ICIs) have revolutionized cancer treatment. However, despite their excellent therapeutic effect, these medications typically result in a broad spectrum of toxicity reactions. Immune-related cardiotoxicity is uncommon but can be potentially fatal, and its true incidence is underestimated in clinical trials. The aim of this study is to assess the incidence and identify risk factors for developing a cardiac event in patients treated with ICIs. Methods: We conducted a single-institution retrospective study, including patients treated with ICIs in our center. The main outcomes were cardiac events (CE) and cardiovascular death. Results: A total of 378 patients were analyzed. The incidence of CE was 16.7%, during a median follow-up of 50.5 months. The multivariable analysis showed that age, a history of arrhythmia or ischemic heart disease, and prior immune-related adverse events were significantly associated with CE. Conclusion: CE during ICI treatment are more common than currently appreciated. A complete initial cardiovascular evaluation is recommended, especially in high-risk patients, being necessary a multidisciplinary approach of a specialized cardio-oncology team.

12.
Rev Port Cardiol ; 41(8): 637-645, 2022 Aug.
Artigo em Inglês, Português | MEDLINE | ID: mdl-36073260

RESUMO

OBJECTIVE: To assess one-year outcomes in patients with persistent and long-standing persistent atrial fibrillation (AF) treated by catheter ablation. METHODS: A retrospective observational study was conducted of consecutive patients referred for catheter ablation of persistent or long-standing persistent AF between May 2016 and October 2018. Patients underwent two different ablation strategies: pulmonary vein isolation (PVI) plus complex fractionated atrial electrograms (CFAE) (from May 2016 to June 2017) or a tailored approach (from July 2017 to October 2018). The overall recurrence rate at one year was analyzed. The secondary endpoint was arrhythmia recurrence according to the type of AF (persistent vs. long-standing persistent AF) and according to the ablation strategy employed. RESULTS: During the study period, 67 patients were included (40% with long-standing persistent AF). During a mean follow-up of 16±6 months, 27% of the patients had arrhythmia recurrence. Patients with long-standing persistent AF had a higher recurrence rate than those with persistent AF (44.4% vs. 15%, p=0.006), while patients who underwent a tailored approach presented better outcomes than those undergoing PVI plus CFAE ablation (17.5% vs. 40.7%, p=0.024). Ablation strategy (HR 6.457 [1.399-29.811], p=0.017), time in continuous AF (HR 1.191 [1.043-1.259], p=0.010) and left atrial volume index (HR 1.160 [1.054-1.276], p=0.002) were independent predictors of arrhythmia recurrence. CONCLUSION: Catheter ablation is an effective treatment for patients with persistent and long-standing persistent AF. Patients with persistent AF and those undergoing a tailored approach presented lower arrhythmia recurrence.

13.
Cancers (Basel) ; 14(16)2022 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-36011034

RESUMO

BACKGROUND: Artificial intelligence (AI) has contributed substantially in recent years to the resolution of different biomedical problems, including cancer. However, AI tools with significant and widespread impact in oncology remain scarce. The goal of this study is to present an AI-based solution tool for cancer patients data analysis that assists clinicians in identifying the clinical factors associated with poor prognosis, relapse and survival, and to develop a prognostic model that stratifies patients by risk. MATERIALS AND METHODS: We used clinical data from 5275 patients diagnosed with non-small cell lung cancer, breast cancer, and non-Hodgkin lymphoma at Hospital Universitario Puerta de Hierro-Majadahonda. Accessible clinical parameters measured with a wearable device and quality of life questionnaires data were also collected. RESULTS: Using an AI-tool, data from 5275 cancer patients were analyzed, integrating clinical data, questionnaires data, and data collected from wearable devices. Descriptive analyses were performed in order to explore the patients' characteristics, survival probabilities were calculated, and a prognostic model identified low and high-risk profile patients. CONCLUSION: Overall, the reconstruction of the population's risk profile for the cancer-specific predictive model was achieved and proved useful in clinical practice using artificial intelligence. It has potential application in clinical settings to improve risk stratification, early detection, and surveillance management of cancer patients.

14.
BMC Cancer ; 22(1): 732, 2022 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-35790916

RESUMO

BACKGROUND: The survival of patients with lung cancer has substantially increased in the last decade by about 15%. This increase is, basically, due to targeted therapies available for advanced stages and the emergence of immunotherapy itself. This work aims to study the situation of biomarker testing in Spain. PATIENTS AND METHODS: The Thoracic Tumours Registry (TTR) is an observational, prospective, registry-based study that included patients diagnosed with lung cancer and other thoracic tumours, from September 2016 to 2020. This TTR study was sponsored by the Spanish Lung Cancer Group (GECP) Foundation, an independent, scientific, multidisciplinary oncology society that coordinates more than 550 experts and 182 hospitals across the Spanish territory. RESULTS: Nine thousand two hundred thirty-nine patients diagnosed with stage IV non-small cell lung cancer (NSCLC) between 2106 and 2020 were analysed. 7,467 (80.8%) were non-squamous and 1,772 (19.2%) were squamous. Tumour marker testing was performed in 85.0% of patients with non-squamous tumours vs 56.3% in those with squamous tumours (p-value < 0.001). The global testing of EGFR, ALK, and ROS1 was 78.9, 64.7, 35.6% respectively, in non-squamous histology. PDL1 was determined globally in the same period (46.9%), although if we focus on the last 3 years it exceeds 85%. There has been a significant increase in the last few years of all determinations and there are even close to 10% of molecular determinations that do not yet have targeted drug approval but will have it in the near future. 4,115 cases had a positive result (44.5%) for either EGFR, ALK, KRAS, BRAF, ROS1, or high PDL1. CONCLUSIONS: Despite the lack of a national project and standard protocol in Spain that regulates the determination of biomarkers, the situation is similar to other European countries. Given the growing number of different determinations and their high positivity, national strategies are urgently needed to implement next-generation sequencing (NGS) in an integrated and cost-effective way in lung cancer.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Biomarcadores Tumorais/análise , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Carcinoma Pulmonar de Células não Pequenas/epidemiologia , Carcinoma Pulmonar de Células não Pequenas/terapia , Demografia , Receptores ErbB/genética , Receptores ErbB/uso terapêutico , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/epidemiologia , Neoplasias Pulmonares/terapia , Estudos Prospectivos , Proteínas Tirosina Quinases , Proteínas Proto-Oncogênicas , Receptores Proteína Tirosina Quinases , Espanha/epidemiologia
15.
J Arrhythm ; 38(3): 346-352, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35785367

RESUMO

Background: The use of the Ablation Index (AI) software for paroxysmal atrial fibrillation (AF) has been associated with higher acute effectiveness and higher 1-year arrhythmia freedom. There is, however, a lack of data concerning longer follow-up. We aim to evaluate the 2-year outcomes after a standardized AI-guided pulmonary vein isolation (PVI). Methods: Prospective, multicenter study of consecutive patients referred for paroxysmal AF ablation from January 2018 to July 2019. PVI was guided by a tailored AI value (≥500 for anterior segment, ≥450 for the roof segments and inferior segments, and 400 for the posterior wall) and an ILD ≤6 mm. The primary endpoints were acute and long-term effectiveness. Results: The study included 218 (842 PV) patients (61% males, median age of 60 [IQR 49-68] years) with paroxysmal AF. First-pass isolation was obtained in 93% of the patients, with an acute reconnection occurring in 10.6% of the patients (3.2% of the PV) following adenosine trial. After a median follow-up of 26 (IQR 20-30) months, freedom from any documented atrial arrhythmia was 83.4%, off-AAD. The rate of adverse events was 1.4%. Although procedural parameters differ across centers (p < 0.001), the acute (p = 0.56) and long-term effectiveness (p = 0.83) were consistent between centers. Conclusions: Patients with paroxysmal AF submitted to an AI-guided PVI workflow presented high arrhythmia freedom at 2-years of follow-up.

16.
J Cardiovasc Electrophysiol ; 33(8): 1725-1733, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35637604

RESUMO

PURPOSE: Since the widespread availability of contact-force sensing catheters, the need for a waiting period after pulmonary vein isolation (PVI) has not been reassessed. We aim to evaluate whether a waiting period is still necessary after PVI guided by the ablation Index (AI). METHODS: Prospective, multicenter, randomized study of consecutive patients referred for paroxysmal atrial fibrillation (AF) ablation from May 2019 to February 2020. Patients were randomized in a 1:1 ratio to PVI with versus without a waiting period of 20 min. Acute pulmonary vein (PV) reconnection after adenosine challenge was the primary endpoint. A per-protocol analysis was designed to determine whether a strategy of dismissing the waiting period after PVI was noninferior to waiting for 20 min for identifying acute PV reconnection. PVI was guided by tailored AI values and an interlesion distance ≤6 mm. RESULTS: During the enrollment period, 167 patients (56% males, mean age of 57 ± 14 years) fulfilled the study inclusion criteria - 84 patients (308 PV) in the waiting period group (Group A) and 83 patients (314 PV) in the group without a waiting period (Group B). Acute PV reconnection was identified in 3.8% (95% confidence interval [CI], 1.7%-5.9%) of PVs in the study group B compared to 2.9% (95% CI, 1.0%-4.8%) of PVs in the Group A (p = .002 for non-inferiority). At 1-year follow-up, there was no significant difference in arrhythmia recurrence between groups (9.5% in Group A vs. 9.6% in Group B, hazard ratio: 1.03 [95% CI, 0.39-2.73], p = .98). CONCLUSION: In paroxysmal AF patients submitted to ablation, a tailored PVI guided by the AI rendered a 20-min waiting period unnecessary.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Software , Resultado do Tratamento
17.
J Interv Card Electrophysiol ; 65(1): 115-121, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35469051

RESUMO

BACKGROUND: There are conflicting data regarding the relationship between high-sensitivity cardiac Troponin I (Hs-cTnI) and the ablation effectiveness quotient (AEQ) with arrhythmia recurrence following atrial fibrillation (AF) ablation. Our goals were to evaluate the impact of the Ablation Index (AI) software on Hs-cTnI and AEQ levels and to assess whether these markers are predictors of arrhythmia recurrence. METHODS: Prospective single-center study of 75 consecutive patients referred for paroxysmal AF ablation from October 2017 to January 2019. Procedural endpoints and 2-year outcomes were assessed and compared to those of 75 propensity score-matched patients submitted to non-AI-guided pulmonary vein isolation (PVI) [control group]. RESULTS: Compared to the control group, patients having AI-guided PVI had lower Hs-cTnI values (1580 [IQR 1180-2140] ng/L vs. 2600 [IQR 1840 - 3900], p < 0.001) and a lower AEQ (0.9 [IQR 0.6-1.2] ng/L/s vs. 1.4 [0.8-1.6] ng/L/s, p < 0.001). After a median follow-up of 26 (IQR 20-32) months, there was a significant reduction in arrhythmia recurrence in the AI group (15% vs. 31%, HR 0.67 [95% CI, 0.32-1.40], p = 0.02). However, neither Hs-cTnI nor AEQ was predictors of arrhythmia recurrence in AI-guided PVI. CONCLUSIONS: The use of the AI software led to reduced levels of Hs-cTnI and lower AEQ in AF patients submitted to PVI. However, none of these markers predicted arrhythmia recurrence.


Assuntos
Arritmias Cardíacas , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Arritmias Cardíacas/cirurgia , Fibrilação Atrial/cirurgia , Biomarcadores , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento , Troponina I
18.
Curr Oncol Rep ; 24(2): 135-149, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35061192

RESUMO

PURPOSE OF REVIEW: Circadian rhythms impose daily rhythms a remarkable variety of metabolic and physiological functions, such as cell proliferation, inflammation, and DNA damage response. Accumulating epidemiological and genetic evidence indicates that circadian rhythms' disruption may be linked to cancer. The integration of circadian biology into cancer research may offer new options for increasing cancer treatment effectiveness and would encompass the prevention, diagnosis, and treatment of this disease. RECENT FINDINGS: In recent years, there has been a significant development and use of multi-modal sensors to monitor physical activity, sleep, and circadian rhythms, allowing, for the very first time, scaling accurate sleep monitoring to epidemiological research linking sleep patterns to disease, and wellness applications providing new potential applications. This review highlights the role of circadian clock in tumorigenesis, cancer hallmarks and introduces the state-of-the-art in sleep-monitoring technologies, discussing the eventual application of insights in clinical settings and cancer research.


Assuntos
Relógios Circadianos , Neoplasias , Carcinogênese , Relógios Circadianos/genética , Ritmo Circadiano/genética , Humanos , Sono
19.
J Cardiovasc Pharmacol ; 79(1): e87-e93, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34775425

RESUMO

ABSTRACT: Digoxin (DG) use in patients with heart failure with reduced ejection fraction (HFrEF) and sinus rhythm remains controversial. We aimed to assess the prognostic effect of DG in patients in sinus rhythm submitted to cardiac resynchronization therapy (CRT). Retrospective study including 297 consecutive patients in sinus rhythm, with advanced HFrEF submitted to CRT. Patients were divided into 2 groups: with DG and without DG (NDG). During a mean follow-up of 4.9 ± 3.4 years, we evaluated the effect of DG on the composite end point defined as cardiovascular hospitalization, progression to heart transplantation, and all-cause mortality. Previous to CRT, 104 patients (35%) chronically underwent DG and 193 patients (65%) underwent NDG treatment. The 2 groups did not differ significantly regarding HF functional class, HF etiology, QRS, and baseline left ventricular ejection fraction. The proportion of responders to CRT was similar in both groups (54% in DG vs. 56% in NDG; P = 0.78). During the long-term follow-up period, the primary end point occurred in a higher proportion in DG patients (67 vs. 48%; P = 0.002). After adjustment for potential confounders, DG use remained as an independent predictor of the composite end point of CV hospitalization, heart transplantation, and all-cause mortality [hazards ratio = 1.58; confidence interval, 95 (1.01-2.46); P = 0.045]. In conclusion, in patients in sinus rhythm with HFrEF submitted to CRT, DG use was associated with CV hospitalization, progression to heart transplant, and all-cause mortality.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiotônicos/uso terapêutico , Digoxina/uso terapêutico , Insuficiência Cardíaca/cirurgia , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Cardiotônicos/efeitos adversos , Causas de Morte , Digoxina/efeitos adversos , Progressão da Doença , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Transplante de Coração , Humanos , Masculino , Pessoa de Meia-Idade , Admissão do Paciente , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
20.
J Interv Card Electrophysiol ; 63(2): 431-440, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34278545

RESUMO

PURPOSE: The purpose of the study was to investigate the usefulness of the extended early meets late (EEML) feature of the HD Coloring software for confirmation of bidirectional block along an ablation line. METHODS: A single-center prospective observational study of consecutive patients with atypical atrial flutter or persistent atrial fibrillation submitted to catheter ablation including linear lesions from January 2019 to June 2020, with confirmation of bidirectional block across ablation lines assessed with the feature EEML and a multipolar catheter was conducted. Patients were divided into two groups - those with versus those without bidirectional block - and different EEML thresholds were analyzed to assess which one had the better sensitivity and specificity to predict block. RESULTS: During the 24-month enrollment period, a total of 94 patients were included (50% males, mean age of 64 ± 10 years, 60% with structural heart disease) - 55 patients with versus 39 patients without confirmed a bidirectional block. Activation maps were performed during atrial pacing, with a median number of 1340 (interquartile range 1135-2060) points acquired in 11 ± 3 min, and a mean mapped cycle length of 287 ± 51 ms. The EEML feature was highly useful in detecting bidirectional block along ablation lines, with a 25% threshold value showing the highest discriminative performance (area under the curve of 0.93), 95% sensitivity and 92% specificity in predicting block. CONCLUSIONS: The EEML feature of the HD Coloring software is a useful addition to the CARTO mapping system for assessment of block across an ablation line. The threshold value of 25% is the most accurate.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/cirurgia , Flutter Atrial/cirurgia , Feminino , Átrios do Coração/cirurgia , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...